Everything on this page is general lab handling information: how a freeze-dried vial becomes a working solution, and how that solution is loaded into a reusable pen. For the water amount and unit count for any compound in the catalog, use the reconstitution calculator on the main page.

What you need

The sterile rule: everything that touches the solution, or gets punctured by a needle, has to be sterile. Needles, syringes, and pen cartridges come pre-sterilized in sealed packs. Use them straight out of the pack, one time only, and never reuse them. Anything that does not come pre-sterilized, like the top of a vial, gets wiped with an alcohol swab before a needle goes in, every time.

Part 1: Reconstitution

STEP 01

Clean setup

Wash your hands and wipe down the work surface. Set everything out before you start so you are never setting a needle down mid-process.

STEP 02

Swab both tops

Flip the caps off the powder vial and the water vial, swab the rubber stoppers with alcohol, and let them air dry for a few seconds.

STEP 03

Draw the water

Put the syringe needle into the water vial. Push in an amount of air equal to the water you need, then draw the water out. The standard amount for most of the catalog is 2.0 mL. Then take the needle out of the vial.

STEP 04

Add it slowly, down the wall

Put the needle into the powder vial. Angle it so the water runs slowly down the inside wall. Do not spray it straight onto the powder. When the syringe is empty, take the needle out.

STEP 05

Rest and swirl

Let the vial sit a minute, then roll and swirl it gently until everything dissolves. Never shake it. If a little powder is stubborn, give it 15 to 30 minutes resting in the fridge and swirl again.

STEP 06

Check, label, chill

The finished solution should be clear with no particles or cloudiness. Write the compound and the date mixed on the vial, and refrigerate at 36 to 46 °F.

The math, in plain words: the vial size divided by the water added gives the strength per mL. A 20 mg vial in 2.0 mL of water makes 10 mg per mL. On an insulin syringe, 100 units is 1 mL, so at that mix 10 units equals 1 mg. The calculator on the main page works this out per compound so you never have to do it by hand.
Reconstitution calculator

Pick your peptide to fill in the vial size automatically, or type the size in yourself, then enter how much bacteriostatic water you add. The concentration of the resulting lab solution updates as you type.

2.50 mg/mL = 0.25 mg (250 mcg) per 0.1 mL · 10 units on an insulin syringe

For laboratory research use only. The commonly reported ranges above are reference information from published research protocols, not medical advice, and not a recommendation to administer any substance to any person or animal.

Part 2: Prepping a peptide pen

This part starts after Part 1. Your vial is already mixed into a liquid. Now you take that liquid out of the vial and put it into the pen vial (the cartridge) so the pen can use it. Follow the steps in order. Every step says when a needle goes in and when it comes out.

STEP 01

Draw up the liquid

Put a fresh sterile syringe into the mixed vial. Pull the liquid up into the syringe. Take the syringe out of the vial.

STEP 02

Put the vent needle in

Take a second sterile needle, with no syringe on it. Push it into the top of the empty pen vial. Leave it there. This is the vent. It lets the air inside the pen vial get out while you fill it.

STEP 03

Put the fill syringe in

Push the needle of your loaded syringe into the top of the pen vial, next to the vent needle. Use two different length needles if you can, or at least point the two needles in opposite directions. That way, when you push the liquid in, it does not spray straight out of the vent needle.

STEP 04

Fill it slow

Push the plunger slow until the pen vial is full. The air inside comes out through the vent needle as the liquid goes in.

STEP 05

Take both needles out

When the pen vial is full, take the vent needle out first. Then take the fill syringe out.

STEP 06

Hold it up and tap

Hold the pen vial straight up, top pointing up. Tap the side with your finger so all the bubbles float to the top.

STEP 07

Put it in the pen

Put the pen vial into the pen. Screw the pen back together.

STEP 08

Put a new needle on

Screw a fresh pen needle onto the end of the pen. Take both caps off the needle.

STEP 09

Push the air out

Hold the pen straight up, needle pointing up. Dial 2 to 5 units at a time. Press down slowly and keep an eye on the air bubble and the tip of the needle, watching to see if liquid is coming out. Make sure all the air gathers in one spot at the tip of the vial, right where it needs to escape. You can stop as soon as you see a small drop of liquid show up at the tip of the needle. When you see the drop, check and make sure the bubble is completely gone. If any bubble is left, repeat this step until all the air is out. Then you are done with this step.

STEP 10

Dial your number

Dial the pen to the unit number the calculator gave you for your mix. That is your setting. The ticks, the small marks on the pen, are in units, the same units the calculator gives you. So if the calculator says 20 units, dial to the 20 tick.

STEP 11

When you are done

If you skipped Step 10, or you are not going to take your dose right now, do this instead. Take the needle off and throw it in a sharps container. Put the pen in the fridge. When you are ready to take your dose, first wipe all around the top of the pen vial with an alcohol swab, the spot where the needle is going to puncture it. Let it dry for a few seconds. Then put a fresh needle on.

Storage clock and warning signs

A filled cartridge follows the same clock as a mixed vial: refrigerated, and recommended to use within about 30 days. Past that, check it before each use. The main concern past that window is bacterial growth. Discard any solution that looks cloudy, discolored, or has particles floating in it, and start fresh.